| Functions |
Description |
| Card Open Door |
Connect wiegand reader or RS-485 reader |
| Card + PIN Open Door |
1. Connect external SK10K, SK100K-CN
reader via wiegand or RS-485 connector
2. Connect external SK100K keypad reader via RS-485 connector
3. Choose either PIN open door or Card ID open door
4. Card + PIN: 4 digits PIN; PIN Only : 8 digits PIN
|
| PIN Open Door |
| Card ID Open Door |
| Fingerprint Open Door |
Connect SK fingerprint card reader via wiegand.
At the same time the following mode can be implemented: Card + Fingerprint,
ID + Fingerprint, Fingerprint + PIN, Card + Fingerprint + PIN, ID + Fingerprint + PIN,
Card Only, Card + PIN, PIN Only , Card ID Only etc. |
| Connect External 26/32 Wiegand Card Reader |
Yes |
| Free Wiegand Setup |
Yes. Can set low battery voltage alarm when use with long range card reader. |
| Connect External Keypad Reader |
1. HID wiegand keypad reader
2. SK series keypad reader(inclusive chinese series keypad reader and SK100K keypad reader) |
| Connect External SK Fingerprint Reader |
Via Wiegand |
| Communicate with PC |
RS-232/485 or TCP/IP (require TCP/IP converter) |
| Push Button Open Door |
Yes |
| Door Force Open Alarm |
Yes |
| Door Open Too Long Alarm |
Door open delay can be set from 1~255
seconds. Factory default is 5 seconds. Alarm can be
disabled. |
| Add & Delete Cards During Offline |
Yes |
| Multi-cards Verification |
Max. 8 cards |
| Key Press Open Door |
Using controller's keypad to open door. Factory default is set to false |
| Invalid PIN Control |
Through process control,diabled controller or card reader when detected invalid PIN |
| Same Card Delay Control |
0~255 seconds. Factory default is 0 |
| Time Zone Control |
32 groups of time zone |
| Holiday Control |
Yes |
| Report Loss Card |
Yes |
| Card Validity Control |
Yes |
| Door Auto Release Time Zone |
Yes |
| Dynamic adjustment |
Yes |
| Connect External Printer |
Yes |
| Alarm Event Output |
Via 3rd port |
| Anti-passback |
Yes |
| Anti-tailgating |
Yes |
| Time Correction |
Yes |
| Card No. Output Byte |
1~4. Default is 3 |
| Card Display Format |
HEX,DEC,ABA,USER CODE. Default is
ABA |
| Communication Monitoring |
Yes |
| PIN Control |
Can be set to "No PIN Control". Default
is yes |
| Time Zone Control |
Can be set to "No Time Zone Control" Default is yes |
| Tamper Alarm |
Built-in Tamper switch. Trigger alarm event to PC when device is force open. |
| Reset Door Open Too Long |
Yes |
| Terminal Resistance |
Setup using jumper |
| Automatic Monitoring |
Yes (Auto DI) |
| Automatic Control Function |
Yes (Auto DO) |
| Flow Control |
Yes |
| RS-485 Reader ID Setup |
Can be set via controller |
| Reader and Door Relationship |
Can be reset |
| Door Sensor Alarm Channel |
Can be set |
| Cancel TTL due to door status changed |
Yes |
| Door Interlocking |
Can be set on 2 doors or more doors |
| Parameters |
SK400 |
SK200 |
| CPU |
16 bits |
| No. of Doors Controlled |
4 |
2 |
| Connect Wiegand Reader |
8 |
4 |
| Connect RS-485 Reader |
8 |
4 |
| TTL Alarm Input |
8 |
8 |
| Door Sensor Signal |
4 |
2 |
| Push Button Signal |
4 |
2 |
| TTL Alarm Output |
8,5V/300mA |
8,85V/300mA8 |
| Alarm Relay |
1,12V/1A |
1, 12V/1A |
| Door Relay |
4, 12V/1A |
2, 12V/1A |
| Tamper Switch |
1 |
1 |
| Card Capacity |
20000 |
20000 |
| Transaction Capacity |
20000 |
20000 |
| COM Port |
3, one is using RS-485 to communicate with PC, one is for communicating with RS-485 reader and another one using RS-232 to communicate with printer or other PC.
|
| Baud Rate |
1200-19200bps, default is 19200bps |
| Device ID Setup |
001-254, default is 1 |
| Rechargeable Battery |
Data store up to 6 months without power |
| Keypad |
3x4, brightly green backlight |
| LCD |
16x2 dots, brightly blue backlight |
| Buzzer |
1 with valid and invalid indicator |
| Power Supply |
9-30VDC,300mA |
| Operation Temperature |
-10~50 ℃ |
| Dimension |
151×105×35mm |
| Housing |
ABS flame-resistant, silvery gray color |